Power Quality Lightning Arrester
Main Secondary
|
|
The PQLAMSä is
a complete system designed to protect commercial and industrial facilities from the
damaging effects of lightning.
|
Main Features:
|
Panel box mounting for easy
installation
60 kA of lightning discharge
current by 10 x 350 us test waveform
Suitable for 1-2-3 phase WYE
or DELTA power circuits up to 400 volts common mode.
Utilizes the patented ARC Chopping principle
Protection of secondary power
mains from damaging lightning currents on conductor cables.
Can cope with surge voltages
caused by remote strikes as well as loadings from direct lightning strikes.
|
| The PQLAMSä lightning protection system can handle the new test waveform
standard 10 x 350 microseconds, a true performance test wave form. The 350 microsecond is
representative of typical lightning strikes. PQLAMSä can
discharge 60 kA of this waveform and survive. This waveform exceeds the energy level
currently represented in the standard ANSI/IEEE, 8 x 20 microsecond waveform as defined in
C62.41. |
|
Since the PQLAMSä contains no decaying components,
repeated lightning events can be shunted safely to a low impedance ground connected of 10
Ohms or less. The PQLAMSä panel system is the only
secondary listed arrestor available utilizing the ARC Chopping Principle. The 4 x 10
microsecond duty cycle test was performed on the PQLAMSä to
10 kA. This test would destroy or quickly decay surge arrestors containing common metal
oxide varistors of MOVs. |
|
| ARC Chopping
Operating Principle |
|
The PQLAMSä enclosure systems is the first line of
protection of a facility. The ARC Chopping Principle guides the lightning transient down
the center of the horns to the crash plate. From the crash plate the lightning arc wraps
around the outside of the horns and breaks down into smaller arcs. These smaller arcs self
extinguish. In the event of the module failing, the special delay fuse will open and
remove the short module from the parallel installation circuit. The PQLAMSä enclosure
system provides easy installation for all common 1-2-3 phase secondary electrical
distribution panels. The PQLAMSä protection system is
installed after the primary circuit fusing. |
|