Merchant services

      since 1993   

PQ Synergy tm 2010 Bangkok, Thailand September 27th, 28th and 29th 2010

                   NEW!!   SMART GRID ASIA    NEW!!

     US Flag

IEEE, NFPA, Yuma Chamber of Commerce, Better Business Bureau, Veterans Business Directory, Central Contractor Registration (CCR)

Home

UPS Systems

UPS Batteries

Battery Chargers

WheelChair/
Scooter Batteries

Alarm Batteries

Common Battery Sizes


Power Monitors

Ground Fault Monitoring

Power Conditioners

Dranetz-BMI Power Products

    Basic Starter Kit

    Advanced User Starter Kit

    Precision Split Current Transformers


 

 Quality Power Batteries, Inc.

Promote Your Page Too


 

ADDRESS:    
642 E 39th Place 

Suite  #5
Yuma, AZ 85365

MapQuest Logo Concept Sketch 1

800-255-5545

928-344-9008                                             
                
   

                                               

 

BIDHISS I Specifications

Model

Power Rating

Voltage

Load Capacity Amps

Conditioner Protection Method*

Load Regulation +/-  %

Efficiency

Number of Outlets

Dimensions

H x W x D (in.)

Weight

(lbs)

PQC11007 78VA 120 0.7 TB 3% 96% 2 3.50 x 4.25 x 6.75 5
PQC1101 120VA 120 1.0 TB 3% 96% 2 3.50 x 4.25 x 6.75 5
PQC1101.5 180VA 120 1.5 TB 3% 96% 2 3.50 x 4.25 x 6.75 6
PQC1102 240VA 120 2 TB 3% 96% 2 3.50 x 4.25 x 6.75 7
PQC1104 360VA 120 3.4 TB 3% 96% 4 4.00 x 5.00 x 7.50 10
PQC1105 480VA 120 4.2 TB 3% 96% 4 4.00 x 5.00 x 7.50 18
PQC1106 600VA 120 5 CB 3% 96% 4 4.00 x 8.00 x 11.75 20
PQC1107 720VA 120 6 CB 3% 96% 4 4.00 x 8.00 x 11.75 21
PQC1108 840VA 120 6.7 CB 3% 96% 4 4.00 x 8.00 x 11.75 23
PQC1110 1000VA 120 8.4 CB 3% 96% 6 6.50 x 10.50 x 16.00 36
PQC1115 1500VA 120 12 CB 3% 96% 6 6.50 x 10.50 x 16.00 39
PQC1120 2000VA 120 16 CB 3% 96% 6 6.50 x 10.50 x 16.00 42

 

Medical Grade Units- (UL 544 Listed)

 

Model

Power Rating

Voltage

Load Capacity Amps

Conditioner Protection Method*

Load Regulation +/-  %

Efficiency

Number of Outlets

Dimensions

H x W x D (in.)

Weight

(lbs)

PQC1102-MED 240VA 120 2 TB 3% 96% 2 3.50 x 4.25 x 6.75 13
PQC1104-MED 360VA 120 3 TB 3% 96% 2 3.50 x 4.25 x 6.75 14
PQC1105-MED 480VA 120 4 TB 3% 96% 4 4.00 x 5.00 x 7.50 17
PQC1106-MED 600VA 120 5 TB 3% 96% 4 4.00 x 5.00 x 7.50 18
PQC1107-MED 720VA 120 6 CB 3% 96% 4 4.00 x 8.00 x 11.75 20
PQC1108-MED 840VA 120 7 CB 3% 96% 4 4.00 x 8.00 x 11.75 22
PQC1110-MED 1000VA 120 8.3 CB 3% 96% 4 4.00 x 8.00 x 11.75 32
PQC1112-MED 1200VA 120 10 CB 3% 96% 6 6.50 x 10.50 x 16.00 44
PQC1115-MED 1500VA 120 12 CB 3% 96% 6 6.50 x 10.50 x 16.00 43
PQC1120-MED 2000VA 120 16 CB 3% 96% 6 6.50 x 10.50 x 16.00 52

Other combinations of input and output voltages, 50/60Hz, and three phase units available.

  • Impulse and Spike Protection--   All systems will withstand and protect against worst-case powerline disturbances, as defined by ANSI/IEEE C62.41-1980 category A and B ringwave and impulse, up to 600V. With an input of 5000V category A ringwave, let-through of high frequency noise will be <10V NM and 0.5V CM, regardless of phase angle.  

  • Reliability-- All units built to UL 1012 standard.

  • Warranty--All units include a standard 5-year warranty.

  • *Protection-- (Column 5 above) TB = Thermal breaker.   CB = Circuit Breaker.